CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 12 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 1995 kg
The dynamic load will be:
50 repetitions/day:1500 kg
100 repetitions/day:1400 kg
200 repetitions/day:1250 kg
300 repetitions/day:1150 kg
Recommended distance between shrink cuts:
Indoor: 3m – 3,5m
Outdoors: 2m – 3m
Cutting depth: 4 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 12 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 2090 kg
The dynamic load will be:
50 repetitions/day:1620 kg
100 repetitions/day:1500 kg
200 repetitions/day:1340 kg
300 repetitions/day:1245 kg
Recommended distance between shrink cuts:
Indoor: 3m – 3,5m
Outdoors: 2m – 3 m
Cutting depth: 4 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 12 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 2100 kg
The dynamic load will be:
50 repetitions/day:1575 kg
100 repetitions/day:1470 kg
200 repetitions/day:1300 kg
300 repetitions/day:1220 kg
Recommended distance between shrink cuts:
Indoor: 3m – 3,5m
Outdoors: 2m – 3m
Cutting depth: 4 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 12 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 2200 kg
The dynamic load will be:
50 repetitions/day:1705 kg
100 repetitions/day:1562 kg
200 repetitions/day:1400 kg
300 repetitions/day:1302 kg
Recommended distance between shrink cuts:
Indoor: 3m – 3,5m
Outdoors: 2m – 3 m
Cutting depth: 4 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 13 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 2280 kg
The dynamic load will be:
50 repetitions/day:1750 kg
100 repetitions/day:1600 kg
200 repetitions/day:1430 kg
300 repetitions/day:1330 kg
Recommended distance between shrink cuts:
Indoor: 3m – 3,5m
Outdoors: 2m – 3m
Cutting depth: 4 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 13 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 2423 kg
The dynamic load will be:
50 repetitions/day:1875 kg
100 repetitions/day:1730 kg
200 repetitions/day:1550 kg
300 repetitions/day:1435 kg
Recommended distance between shrink cuts:
Indoor: 3m – 3,5m
Outdoors: 2m – 3 m
Cutting depth: 4 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 13 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 2400 kg
The dynamic load will be:
50 repetitions/day:1840 kg
100 repetitions/day:1680 kg
200 repetitions/day:1370 kg
300 repetitions/day:1290 kg
Recommended distance between shrink cuts:
Indoor: 3m – 3,5m
Outdoors: 2m – 3m
Cutting depth: 4 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 13 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 2550 kg
The dynamic load will be:
50 repetitions/day:1960 kg
100 repetitions/day:1802 kg
200 repetitions/day:1630 kg
300 repetitions/day:1512 kg
Recommended distance between shrink cuts:
Indoor: 3m – 3,5m
Outdoors: 2m – 3 m
Cutting depth: 4 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 14 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 2565 kg
The dynamic load will be:
50 repetitions/day:1980 kg
100 repetitions/day:1830 kg
200 repetitions/day:1650 kg
300 repetitions/day:1520 kg
Recommended distance between shrink cuts:
Indoor: 3,5m – 4m
Outdoors: 2,5m – 3,5m
Cutting depth: 4,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 14 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 2755 kg
The dynamic load will be:
50 repetitions/day:2135 kg
100 repetitions/day:1980 kg
200 repetitions/day:1775 kg
300 repetitions/day:1645 kg
Recommended distance between shrink cuts:
Indoor: 3,5m – 4m
Outdoors: 2,5m – 3,5m
Cutting depth: 4,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 14 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 2700 kg
The dynamic load will be:
50 repetitions/day:2070 kg
100 repetitions/day:1932 kg
200 repetitions/day:1728 kg
300 repetitions/day:1590 kg
Recommended distance between shrink cuts:
Indoor: 3,5m – 4m
Outdoors: 2,5m – 3,5m
Cutting depth: 4,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 14 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 2900 kg
The dynamic load will be:
50 repetitions/day:2245 kg
100 repetitions/day:2175 kg
200 repetitions/day:1853 kg
300 repetitions/day:1720 kg
Recommended distance between shrink cuts:
Indoor: 3,5m – 4m
Outdoors: 2,5m – 3,5m
Cutting depth: 4,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 15 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 2850 kg
The dynamic load will be:
50 repetitions/day:2250 kg
100 repetitions/day:2100 kg
200 repetitions/day:1860 kg
300 repetitions/day:1720 kg
Recommended distance between shrink cuts:
Indoor: 3,75m – 4,5m
Outdoors: 3,5m – 4m
Cutting depth: 5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 15 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 3040 kg
The dynamic load will be:
50 repetitions/day:2430 kg
100 repetitions/day:2245 kg
200 repetitions/day:2010 kg
300 repetitions/day:1865 kg
Recommended distance between shrink cuts:
Indoor: 3,75m – 4,5m
Outdoors: 3,5m – 4m
Cutting depth: 5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 15 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 3000 kg
The dynamic load will be:
50 repetitions/day:2350 kg
100 repetitions/day:2200 kg
200 repetitions/day:1950 kg
300 repetitions/day:1805 kg
Recommended distance between shrink cuts:
Indoor: 3,75m – 4,5m
Outdoors: 3,5m – 4m
Cutting depth: 5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 15 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 3200 kg
The dynamic load will be:
50 repetitions/day:2555 kg
100 repetitions/day:2352 kg
200 repetitions/day:2113 kg
300 repetitions/day:1950 kg
Recommended distance between shrink cuts:
Indoor: 3,75m – 4,5m
Outdoors: 3,5m – 4m
Cutting depth: 5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 16 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 3230 kg
The dynamic load will be:
50 repetitions/day:2530 kg
100 repetitions/day:2340 kg
200 repetitions/day:2090 kg
300 repetitions/day:1940 kg
Recommended distance between shrink cuts:
Indoor: 3,75m – 4,5m
Outdoors: 3,5m – 4m
Cutting depth: 5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 16 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 3420 kg
The dynamic load will be:
50 repetitions/day:2735 kg
100 repetitions/day:2528 kg
200 repetitions/day:2265 kg
300 repetitions/day:2095 kg
Recommended distance between shrink cuts:
Indoor: 3,75m – 4,5m
Outdoors: 3,5m – 4m
Cutting depth: 5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 16 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 3400 kg
The dynamic load will be:
50 repetitions/day:2630 kg
100 repetitions/day:2450 kg
200 repetitions/day:2200 kg
300 repetitions/day:2030 kg
Recommended distance between shrink cuts:
Indoor: 3,75m – 4,5m
Outdoors: 3,5m – 4m
Cutting depth: 5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 16 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 3600 kg
The dynamic load will be:
50 repetitions/day:2870 kg
100 repetitions/day:2662 kg
200 repetitions/day:2372 kg
300 repetitions/day:2185 kg
Recommended distance between shrink cuts:
Indoor: 3,75m – 4,5m
Outdoors: 3,5m – 4m
Cutting depth: 5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 17 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 3610 kg
The dynamic load will be:
50 repetitions/day:2830 kg
100 repetitions/day:2620 kg
200 repetitions/day:2335 kg
300 repetitions/day:2165 kg
Recommended distance between shrink cuts:
Indoor: 4m – 5m
Outdoors: 3,5m – 4m
Cutting depth: 5,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 17 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 3800 kg
The dynamic load will be:
50 repetitions/day:3060 kg
100 repetitions/day:2820 kg
200 repetitions/day:2525 kg
300 repetitions/day:2345 kg
Recommended distance between shrink cuts:
Indoor: 4m – 5m
Outdoors: 3,5m – 4m
Cutting depth: 5,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 17 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 3800 kg
The dynamic load will be:
50 repetitions/day:2950 kg
100 repetitions/day:2740 kg
200 repetitions/day:2462 kg
300 repetitions/day:2268 kg
Recommended distance between shrink cuts:
Indoor: 4m – 5m
Outdoors: 3,5m – 4m
Cutting depth: 5,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 17 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 4000 kg
The dynamic load will be:
50 repetitions/day:3210 kg
100 repetitions/day:2950 kg
200 repetitions/day:2649 kg
300 repetitions/day:2465 kg
Recommended distance between shrink cuts:
Indoor: 4m – 5m
Outdoors: 3,5m – 4m
Cutting depth: 5,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 18 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 3895 kg
The dynamic load will be:
50 repetitions/day:3150 kg
100 repetitions/day:2920 kg
200 repetitions/day:2620 kg
300 repetitions/day:2400 kg
Recommended distance between shrink cuts:
Indoor: 4m – 5m
Outdoors: 3,5m – 4m
Cutting depth: 6 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 18 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 4133 kg
The dynamic load will be:
50 repetitions/day:3400 kg
100 repetitions/day:3140 kg
200 repetitions/day:2810 kg
300 repetitions/day:2600 kg
Recommended distance between shrink cuts:
Indoor: 4m – 5m
Outdoors: 3,5m – 4m
Cutting depth: 6 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 18 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 4100 kg
The dynamic load will be:
50 repetitions/day:3307 kg
100 repetitions/day:3070 kg
200 repetitions/day:2742 kg
300 repetitions/day:2525 kg
Recommended distance between shrink cuts:
Indoor: 4m – 5m
Outdoors: 3,5m – 4m
Cutting depth: 6 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 18 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 4350 kg
The dynamic load will be:
50 repetitions/day:3572 kg
100 repetitions/day:3290 kg
200 repetitions/day:2940 kg
300 repetitions/day:2723 kg
Recommended distance between shrink cuts:
Indoor: 4m – 5m
Outdoors: 3,5m – 4m
Cutting depth: 6 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 19 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 4275 kg
The dynamic load will be:
50 repetitions/day:3470 kg
100 repetitions/day:3200 kg
200 repetitions/day:2860 kg
300 repetitions/day:2660 kg
Recommended distance between shrink cuts:
Indoor: 4,25m – 5,5m
Outdoors: 4m – 5m
Cutting depth: 6 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 19 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 4513 kg
The dynamic load will be:
50 repetitions/day:3750 kg
100 repetitions/day:3465 kg
200 repetitions/day:3100 kg
300 repetitions/day:2875 kg
Recommended distance between shrink cuts:
Indoor: 4,25m – 5,5m
Outdoors: 4m – 5m
Cutting depth: 6 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 19 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 4500 kg
The dynamic load will be:
50 repetitions/day:3640 kg
100 repetitions/day:3355 kg
200 repetitions/day:3007 kg
300 repetitions/day:2790 kg
Recommended distance between shrink cuts:
Indoor: 4,25m – 5,5m
Outdoors: 4m – 5m
Cutting depth: 6 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 19 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 4750 kg
The dynamic load will be:
50 repetitions/day:3930 kg
100 repetitions/day:3641 kg
200 repetitions/day:3248 kg
300 repetitions/day:3020 kg
Recommended distance between shrink cuts:
Indoor: 4,25m – 5,5m
Outdoors: 4m – 5m
Cutting depth: 6 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 20 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 4655 kg
The dynamic load will be:
50 repetitions/day:3800 kg
100 repetitions/day:3500 kg
200 repetitions/day:3140 kg
300 repetitions/day:2910 kg
Recommended distance between shrink cuts:
Indoor: 4,25m – 5,5m
Outdoors: 4m – 5m
Cutting depth: 6,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 20 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 4940 kg
The dynamic load will be:
50 repetitions/day:4120 kg
100 repetitions/day:3810 kg
200 repetitions/day:3410 kg
300 repetitions/day:3160 kg
Recommended distance between shrink cuts:
Indoor: 4,25m – 5,5m
Outdoors: 4m – 5m
Cutting depth: 6,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 20 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 4900 kg
The dynamic load will be:
50 repetitions/day:3960 kg
100 repetitions/day:33680 kg
200 repetitions/day:3300 kg
300 repetitions/day:3047 kg
Recommended distance between shrink cuts:
Indoor: 4,25m – 5,5m
Outdoors: 4m – 5m
Cutting depth: 6,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 20 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 5200 kg
The dynamic load will be:
50 repetitions/day:4330 kg
100 repetitions/day:3986 kg
200 repetitions/day:3583 kg
300 repetitions/day:3325 kg
Recommended distance between shrink cuts:
Indoor: 4,25m – 5,5m
Outdoors: 4m – 5m
Cutting depth: 6,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 21 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 5035 kg
The dynamic load will be:
50 repetitions/day:4150 kg
100 repetitions/day:3840 kg
200 repetitions/day:3430 kg
300 repetitions/day:3180 kg
Recommended distance between shrink cuts:
Indoor: 4,5m – 6m
Outdoors: 4m – 5m
Cutting depth: 7 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 21 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 5415 kg
The dynamic load will be:
50 repetitions/day:4510 kg
100 repetitions/day:4170 kg
200 repetitions/day:3730 kg
300 repetitions/day:3465 kg
Recommended distance between shrink cuts:
Indoor: 4,5m – 6m
Outdoors: 4m – 5m
Cutting depth: 7 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 21 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 5300 kg
The dynamic load will be:
50 repetitions/day:4350 kg
100 repetitions/day:4030 kg
200 repetitions/day:3580 kg
300 repetitions/day:3325 kg
Recommended distance between shrink cuts:
Indoor: 4,5m – 6m
Outdoors: 4m – 5m
Cutting depth: 7 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 21 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 5700 kg
The dynamic load will be:
50 repetitions/day:4730 kg
100 repetitions/day:4370 kg
200 repetitions/day:3900 kg
300 repetitions/day:3642 kg
Recommended distance between shrink cuts:
Indoor: 4,5m – 6m
Outdoors: 4m – 5m
Cutting depth: 7 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 22 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 5463 kg
The dynamic load will be:
50 repetitions/day:4530 kg
100 repetitions/day:4180 kg
200 repetitions/day:3740 kg
300 repetitions/day:3470 kg
Recommended distance between shrink cuts:
Indoor: 4,5m – 6m
Outdoors: 4,5m – 6m
Cutting depth: 7 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 22 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 5890 kg
The dynamic load will be:
50 repetitions/day:4925 kg
100 repetitions/day:4550 kg
200 repetitions/day:4065 kg
300 repetitions/day:3775 kg
Recommended distance between shrink cuts:
Indoor: 4,5m – 6m
Outdoors: 4,5m – 6m
Cutting depth: 7 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 22 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 5750 kg
The dynamic load will be:
50 repetitions/day:4750 kg
100 repetitions/day:4365 kg
200 repetitions/day:3920 kg
300 repetitions/day:3660 kg
Recommended distance between shrink cuts:
Indoor: 4,5m – 6m
Outdoors: 4,5m – 6m
Cutting depth: 7 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 22 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 6200 kg
The dynamic load will be:
50 repetitions/day:5168 kg
100 repetitions/day:4780 kg
200 repetitions/day:4275 kg
300 repetitions/day:3950 kg
Recommended distance between shrink cuts:
Indoor: 4,5m – 6m
Outdoors: 4,5m – 6m
Cutting depth: 7 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 23 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 6033 kg
The dynamic load will be:
50 repetitions/day:4920 kg
100 repetitions/day:4540 kg
200 repetitions/day:4070 kg
300 repetitions/day:3765 kg
Recommended distance between shrink cuts:
Indoor: 4,75m – 6,5m
Outdoors: 4,5m – 6m
Cutting depth: 7,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 23 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 6365 kg
The dynamic load will be:
50 repetitions/day:4925 kg
100 repetitions/day:4550 kg
200 repetitions/day:4065 kg
300 repetitions/day:3775 kg
Recommended distance between shrink cuts:
Indoor: 4,75m – 6,5m
Outdoors: 4,5m – 6m
Cutting depth: 7,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 23 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 6350 kg
The dynamic load will be:
50 repetitions/day:5160 kg
100 repetitions/day:4755 kg
200 repetitions/day:4260 kg
300 repetitions/day:3970 kg
Recommended distance between shrink cuts:
Indoor: 4,75m – 6,5m
Outdoors: 4,5m – 3m
Cutting depth: 7,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 23 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 6700 kg
The dynamic load will be:
50 repetitions/day:5168 kg
100 repetitions/day:4780 kg
200 repetitions/day:4275 kg
300 repetitions/day:3950 kg
Recommended distance between shrink cuts:
Indoor: 4,75m – 6,5m
Outdoors: 4,5m – 6m
Cutting depth: 7,5 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 24 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 6413 kg
The dynamic load will be:
50 repetitions/day:5320 kg
100 repetitions/day:4910 kg
200 repetitions/day:4400 kg
300 repetitions/day:4080 kg
Recommended distance between shrink cuts:
Indoor: 4,75m – 6,5m
Outdoors: 4,5m – 6m
Cutting depth: 8 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 24 cm

DOSAGE FIBRATEC V12-AM: 2 kg / m³
The static flexotraction point load that the floor will support for each support point is 6793 kg
The dynamic load will be:
50 repetitions/day:5790 kg
100 repetitions/day:5340 kg
200 repetitions/day:4780 kg
300 repetitions/day:4440 kg
Recommended distance between shrink cuts:
Indoor: 4,75m – 6,5m
Outdoors: 4,5m – 6m
Cutting depth: 8 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 25 – 25 N/mm²

SLAB THICKNESS 24 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 6750 kg
The dynamic load will be:
50 repetitions/day:5585 kg
100 repetitions/day:5145 kg
200 repetitions/day:4630 kg
300 repetitions/day:4300 kg
Recommended distance between shrink cuts:
Indoor: 4,75m – 6,5m
Outdoors: 4,5m – 6ma
Cutting depth: 8 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES

CONCRETE HA 30 – 30 N/mm²

SLAB THICKNESS 24 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³
The static flexotraction point load that the floor will support for each support point is 7150 kg
The dynamic load will be:
50 repetitions/day:6070 kg
100 repetitions/day:5590 kg
200 repetitions/day:5002 kg
300 repetitions/day:4670 kg
Recommended distance between shrink cuts:
Indoor: 4,75m – 6,5m
Outdoors: 4,5m – 6m
Cutting depth: 8 cm
CLICK HERE TO MAKE THE CUTS AT GREATER DISTANCES